Evaluation of Wall Thinning of the Steel Piping after Long Term Operation at Fugen Power Station |
|||||
| Ryosuke ANDO1, Teruyoshi ABE1, Takahisa NAKAMURA1 | |||||
|
1 Japan Atomic Energy Agency, 65-20 Kizaki, Tsuruga , Fukui 914-8585, Japan |
|||||
| Abstract | |||||
|
Wall thinning of serviced carbon steel piping of the secondary cooling system after long term operation of Advanced Thermal prototype Reactor (ATR) Fugen power station has been investigated as a series of evaluation of validity and availability of utilization of serviced materials on research projects focused on aging management.
|
|||||
| Keywords | |||||
| serviced materials, steel piping, wall thinning, FAC, LDI, JSME code, ATR Fugen power station | |||||
|
Full Paper: PDF
|
|||||